Inputs and Outputs are used for the monitoring and controlling of a connected device or receiving signals from that device in order to trigger certain events.
This section provides a list Input/Output electric characteristics inherent in RUT955 routers.
Digital input (DIN1): Logic low 0 - 1.2 V; Logic high 1.8 - 3 V
Digital galvanically isolated input (DIN2): 0 - 30 V
Analog input (voltage mode): 0 – 24 V*
Analog input (current mode): up to 20 mA (commonly used with 4-20 mA standard sensors)
Digital open collector (OC) output: 30 V, 250 mA
SPST relay output: 24 V, 4 A
Digital non-isolated input (in power socket): Logic low 0 - 5 V; Logic high 8 - 40 V
Digital open collector (in power socket) output: 30 V, 300 mA
More information on: https://wiki.teltonika-networks.com/view/RUT955_Input/Output
Hardware Application Examples
More information on https://wiki.teltonika-networks.com/view/RUT955_Hardware_Application_Examples