Inputs and Outputs are used for the monitoring and controlling of a connected device or receiving signals from that device in order to trigger certain events.

This section provides a list Input/Output electric characteristics inherent in RUT955 routers.

  • Digital input (DIN1): Logic low 0 - 1.2 V; Logic high 1.8 - 3 V

  • Digital galvanically isolated input (DIN2): 0 - 30 V

  • Analog input (voltage mode): 0 – 24 V*

  • Analog input (current mode): up to 20 mA (commonly used with 4-20 mA standard sensors)

  • Digital open collector (OC) output: 30 V, 250 mA

  • SPST relay output: 24 V, 4 A

  • Digital non-isolated input (in power socket): Logic low 0 - 5 V; Logic high 8 - 40 V

  • Digital open collector (in power socket) output: 30 V, 300 mA