CAN adapters

Teltonika CAN adapters

  • Teltonika ALL-CAN300
    • SWDate < 2018-01-01 => 3 or 4 digits, not upgradable to 5 digits;
    • SWDate >= 2018-01-01 => 5 digits;
  • Teltonika CAN-CONTROL
  • Teltonika LV-CAN200
    • SWDate < 2018-01-01 => 3 or 4 digits, not upgradable to 5 digits;
    • SWDate >= 2018-01-01 => 5 digits;
  • Teltonika SIMPLE-CAN

...

Teltonika devices cannot write to CAN bus for safety reasons.

Nevertheless, CAN CAN-CONTROL can only send some request commands to CAN bus such as:

  • lvcanopenalldoors = Open [unlock] all doors

  • lvcanclosealldoors = Close [lock] all doors

  • lvcanopentrunk =Open [unlock] trunk

  • lvcanturninglights = One flash of all turn lights ordered trough accidental / blinking turn light switch

References:

ALL-CAN300, LV-CAN200

manufacturing
date:
from
manufacturing
date:
to
HW
revision

digits:
min.
length

digits:
factory
default
digits:
max.
length
screw
position

2017-08-31P145334center
2017-09-012017-12-31P1453

4

4center
2018-01-01
U245(question)5(question)displaced 0,5 cm towards connector

Useful SMS command: lvcangetinfo (Get information about connected CAN Adapter).




LV-BOOT20

Teltonika LV-BOOT20 updates firmware of the following CAN adapters:

  • ALL-CAN300, LV-CAN200: connector cable, ... 10 pins
  • CAN-CONTROL: connector cable, ... (question) / 11 (question)  pins

Update process:

  • start LV-CAN200 Updater;
  • enter standard user name and standard password to log in;