Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 7 Next »

immobilizer

immobilize vehicle leaving geofence

It is possible to do this using Codec12 Protocol, that is designed for the FM device and server communication.

For example:

  • Configure Auto-Geofence on High Priority
  • Eventual Records -> Enable
  • Generate Event -> On Exit
  • Deactivate by -> iButton or Digital Input 2/ Digital Input 3 and connect an additional button for Authorized Driving, would only need to send Voltage higher than 2.5 V to DIN2/DIN3
  • if Vehicle is being stolen and leaves the Auto-Geofence, an event is generated that the vehicle left the Zone, with Event I/O ID 175 ()
  • Server parses the Record and if it finds the Event I/O ID 175 sends GPRS command:
    00000000000000140C01050000000C7365746469676F757420313F010000DED1

This will set DOUT1 to High for Infinite time.

close doors

  1. Send SMS command about opening the doors;
  2. FM device receives SMS command;
  3. FM device sends request to the CAN-CONTROL adapter;
  4. CAN-CONTROL adapter sends request to the vehicle computer about opening the doors.

counting running engine hours

We would recommend to measure the power voltage when ignition switch is ON and:

  • engine OFF (Vacc);
  • engine IDLE (Vidle).

A running engine implies higher power voltages than an engine switched off.

In the configuration then

  • use ignition source from power voltage;
  • set low voltage (mV) halfway between Vacc and Vidle.

Then you will get ignition value = 1 only when the engine is running.

Example:

  • Vacc = 25 V
  • Vidle = 27.5 V
  • => low voltage = 2,600 mV


  • No labels