Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

desktop application

.... getDDDGetDDD

Note

  • Since 2020, GetDDD solution is outdated and not supported any more (new developments and fixes will not be made)

WEB Tacho

ddd.teltonika.lt  or  IP: 212.59.13.226.47.99.61


For all MB Actros 2019-2020 that have CAN2 connected to the tachograph, settings should be:


• "tachoaddrset 251" --> Tachograph address should be default one - 251. Some vehicles had 252 or 253, but it should be default 251

• "setparam 150 250" --> CAN2 baudrate 250

From GEN2 tachographs (VDO 4.0 and Stoneridge 8.0), "alternative DDD download" must be disabled, because such functionality does not work with GEN2 tachos. Regarding the baudrate:

all new GEN2 tachographs mostly uses 250 kbps baudrate (which is default). Only several tacho models uses 500 kbps, but it not that often.


Tachograph address:

Sometimes, some vehicles have another devices connected to the tachograph CAN line. In other words - another CAN device is using to the same address as tachograph.

In such event User must change tachograph address

This can be done using SMS/GPRS command "tachoaddrset"

Address can be read using SMS/GPRS command "tachoaddrget"

Examples (and possible values):

tachoaddrset 250

tachoaddrset 252

tachoaddrset 253

tachoaddrset 254


For GEN2 tachographs, Alternative DDD download MUST be disabled. "aaa bbb setparam 214 0" --> "Param ID:214 New Val:0". Alternative DDD download searches for Driver Card data in different location in tachograph itself


Notes:

  • If you have VPN SIM cards, IP in the configuration and VPN settings should be use instead of ddd.teltonika.lt

    ddd.teltonika.lt --> 212.47.99.61

    So please change device configuration and VPN settings to use 212.47.99.61.

  • Web Tacho support LISLE card reader rack. So with one single USB to one PC you can connect more than 10 company cards. There is different racks, which support 6, 20 or even 120 company cards

    Web Tacho do not support API. Web Tacho support FTP file synchronization, so all downloaded DDD files can be trasfered to your configured FTP server. From device side you will need configure domain and PORT where devices should automatically connect. You will need register devices and create schedules. Devices can be imported via CSV file.

  • TachoWeb  instructions: https://wiki.teltonika-gps.com/view/WEB_Tacho
  • After DDD files are downloaded, various softwares can be used to read them. Teltonika uses "Tachosys File Viewer" (which is paid) --> https://www.tachosys.com/Products/TachographFileViewer. This sofrware can open both GEN1 and GEN2 tachograph files. For GEN1 files, a free software "readesm"

FAQ

Q: Does Web tacho support multiple (e.g. more than 11) car readers connected to one single server?
A: Web Tacho supports LISLE card reader rack. So with one single USB to one PC,  you can connect more than 10 company cards. There is different racks, which support 6, 20 or even 120 company cards.

--

Q: Does Web Tacho support API? (Is there an interface from Teltonika to "Web Tacho" to automatically transfer the downloaded DDD files)?

A: Web Tacho does not support API. Web Tacho supports FTP file synchronization, so all downloaded DDD files can be transfered to your configured FTP server.

--

Q: What do we need to configure?

A: From device side, you will need to configure domain and PORT where devices should automatically connect. You will need to register devices and to create schedules. Devices can be imported via CSV files.

company management > email address

...

Email > Enter user email address (Mandatory): you can configure in "user settings" for each user to receive e-mail messages for failed schedules and Receive e-mail messages with ddd files attached on schedule completion.


Note: When you face issue with DDD donwload,  please write in advance that with older firmware, DDD download was successful if it was the case, Because it will be not possible to downgrade to older firmware due to stability improvements. 


FAQ

Q: After installing Remote Smart Card reader software for 1.0.0 to 3.0.10, company card is no longer connected to the Tacho WEB?

R: Check firewall settings and make sure that PORTS: 29000-29003 are accessible from the inside of the network ( Also when working with Remote Smart Card reader software, it's better to ask for software logs, which are located: C:\Program Files (x86)\Teltonika\SCard Reader\Service\Logs)


...


Digital tachograph monitoring solution


There are two ways to implement software:

...

https://wiki.teltonika.lt/view/Digital_tachograph_monitoring_and_data_reports

Note

Tachograph files from VDO 4.0 are in "GEN2" format and cannot be opened by regular DDD reader (which only support GEN1 formats). So to open GEN2 files, you need to have GEN2 software.

One of the tachograph file viewer software, which support GEN2 files - https://www.tachosys.com/Downloads/Software --> Tachograph File Viewer 3.05

...


Connection and configuration of the tachograph for the FMB640

...

To use tachograph, devices must have:

  • Tachograph live data (K-line) - data from digital tachograph
  • Remote tachograph file download
  • Teltonika Web Tacho application or other software to download files and monitor data 
  • FMS CAN Data (J1939)


FAQ

...


Connection of the tachograph for the FM6320

C5+C7 connection is used for DDD files download

D8 K-Line used to monitor tachograph events.

These are parameters you can get from K-Line:

Drive recognize

Driver 1 working state

Driver 2 working state

Overspeed

Driver 1 card

Driver 2 card

Driver 1 time rel state

Driver 2 time rel state

Speed

Odometer

Distance of current journey

Timestamp

Driver 1 ID MSB

Driver 1 ID LSB

Driver 2 ID MSB

Driver 2 ID LSB


FAQ

Q:  Which AVL-ID should I  use to receive the "Tacho Data Source"?

A:  AVL_ID for "Tacho Data Source" is AVLID=48


...

TAVL Management

Change Password

To change any Login password, you should select the login, press "Edit" button. Then type in the new password into the "Password" and "Verify Password" fields. After these actions simply press "Save" button. So, new password will be saved.

...