Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

FMB120 can perform tasks on remote objects, such as monitoring engine status, controlling truck’s door etc.

DIfference Table

Features

FMB120

FMB130

DOUT

2

3

Negative Input

-

✓(Digital Input 2)

Impulse Inputs

✓(Digital Input 1, Digital Input 2)

1-Wire

Dimension

65 x 56.6 x 18.9 mm

65 x 56.6 x 20.6 mm

Wiring Scheme comparison

...

2x6 socket Pin

Common

FMB120

FMB130

1

VCC (10-30) V DC (+)

Power supply (+10 -30 V DC).

2

(warning)

AIN 1

Analog input, channel 1. Input range: 0-30 V DC.

DOUT 3

Digital output, channel 3. Open collector output. Max. 3,3 A DC.

3

AIN 2 / DIN 3

Analog input, channel 2. Input range: 0-30 V DC / Digital input, channel 3.

4

(warning)

DIN 2

Digital input, channel 2.

DIN 2-N/AIN1

  • Digital input, channel 2;

  • Negative input;

  • Analog input, channel 1, Input range: 0-30 V DC.

5

DIN 1

Digital input, channel 1.

6

INPUT 6

TX EXT (LVCAN – TX).

7

GND (-)

Ground.

8

DOUT 1

Digital output, channel 1. Open collector output. Max. 3,3 A DC

9

DOUT 2

Digital output, channel 2. Open collector output. Max. 3,3 A DC.

10

1WIRE POWER

+3,8 V output for 1–Wire devices.

11

1WIRE DATA

Data for 1–Wire devices.

12

INPUT 5

RX EXT (LVCAN - RX).

Image AddedImage Added

FMB120 FMB130

...

FAQ

Q: How does this negative input work?

...

A: Negative pulses can be configured in the system window in the mass detection input mode. For this, only one of DIN2/AIN1 wire can be used. If you use another DIN or AIN input, you only need to configure the I/O tab by activating it.

--

Q: How to Configure configure DIN/AIN for flexible remote monitoring and control?

...

A: It detects automatically if AIN or DIN is used.

Hint:

  • Impulse counter can be configured by connecting DIN1 or DIN2 wire (one of them). If you will use DIN1 as impulse counter there is no any configuration needed, except enabling DIN1 I/O element.

  • Negative input can be configured by using only DIN2 wire, and this should be configured as "Ground sense" Input mode.