usage scenario
immobilizer
immobilize vehicle leaving geofence
...
This will set DOUT1 to High for Infinite time.
close doors
- Send SMS command about opening the doors;
- FM device receives SMS command;
- FM device sends request to the CAN-CONTROL adapter;
- CAN-CONTROL adapter sends request to the vehicle computer about opening the doors.
counting running engine hours
...
- Vacc = 25 V
- Vidle = 27.5 V
- => low voltage = 2,600 mV
Geofence using sms
Q: How to activate geofencing notifications using SMS?
A: In this case You should simply create the recipient specifying required GSM number and then while creating new Geofencing rule (or editing current rule) add as a recipient Your created recipient that uses GSM number
Time zone configuration
It is recommends to you use NITZ+NTP time synchronization, because firstly device will try to get time from NITZ (Mobile operator which you are connected) so you should have time (GMT+1) depending where you are in the world and if the device will switch to NTP, there is (GMT+0).
- You can configure your device NTP server which is local on your country to have a valid time and set time resync 1 hour. Device will update your device time every hour.
GPS issue
-If you have a problem with gps connection please change the movement start delay to 10s by SMS/GPRS commands:
setparam 19001:10
.Bin file
Q: How to parse .bin file?
A: .bin file should be added to TAVL server to get records parsed. Device should be added as object to TAVL server.