...
FMB120 can perform tasks on remote objects, such as monitoring engine status, controlling truck’s door etc.
DIfference Table
Features | FMB120 | FMB130 |
---|---|---|
DOUT | 2 | 3 |
Negative Input | - | ✓(Digital Input 2) |
Impulse Inputs | ✓(Digital Input 1, Digital Input 2) | |
1-Wire | ||
Dimension | 65 x 56.6 x 18.9 mm | 65 x 56.6 x 20.6 mm |
Wiring Scheme comparison
...
2x6 socket Pin | Common | FMB120 | FMB130 |
1 | VCC (10-30) V DC (+) Power supply (+10 -30 V DC). | ||
2 | AIN 1 Analog input, channel 1. Input range: 0-30 V DC. | DOUT 3 Digital output, channel 3. Open collector output. Max. 3,3 A DC. | |
3 | AIN 2 / DIN 3 Analog input, channel 2. Input range: 0-30 V DC / Digital input, channel 3. | ||
4 | DIN 2 Digital input, channel 2. | DIN 2-N/AIN1
| |
5 | DIN 1 Digital input, channel 1. | ||
6 | INPUT 6 TX EXT (LVCAN – TX). | ||
7 | GND (-) Ground. | ||
8 | DOUT 1 Digital output, channel 1. Open collector output. Max. 3,3 A DC | ||
9 | DOUT 2 Digital output, channel 2. Open collector output. Max. 3,3 A DC. | ||
10 | 1WIRE POWER +3,8 V output for 1–Wire devices. | ||
11 | 1WIRE DATA Data for 1–Wire devices. | ||
12 | INPUT 5 RX EXT (LVCAN - RX). |
FMB120 FMB130
...
FAQ
Q: How does this negative input work?
...
A: The main purpose is to connect to seat belts or to doors (open or closed) to get negative input, to know if the seat belts is attached or detached.
--
Q: What is impulse input used for?
A: The main reason is used for counting pulses to get information regarding the fuel level. Mainly for fuel impulses counting.
--
Q: How to configure impulse input?
A: To configure impulse counter, you should use DIN1/DIN2 and on this DIN, it will count impulses (max 50HZ) and send to the server. More information: https://wiki.teltonika-gps.com/view/Impulse_counter
--
Q: How to configure a digital input as negative or impulse input?
A: The digital input must be configured as ground sense for the impulse input as DIN2/AIN1, If you use DIN1 as impulse counter then you do not have to configure anything, just activate the I/O parameter of DIN1.
--
Q: How to configure digital/analogue inputs/negative input?
A: Negative pulses can be configured in the system window in the mass detection input mode. For this, only one of DIN2/AIN1 wire can be used. If you use another DIN or AIN input, you only need to configure the I/O tab by activating it.
--
Q: How to configure DIN/AIN for flexible remote monitoring and control?
A: For AIN, you can use another AIN input and for DIN, There are also 3 DIN inputs.
--
Q: How to deal with flexible inputs configuration?
A: It detects automatically if AIN or DIN is used.
Hint:
Impulse counter can be configured by connecting DIN1 or DIN2 wire (one of them). If you will use DIN1 as impulse counter there is no any configuration needed, except enabling DIN1 I/O element.
Negative input can be configured by using only DIN2 wire, and this should be configured as "Ground sense" Input mode.